Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement

Ramsey, Danielle, Ramdharry, Gita, Scoto, Mariacristina, Muntoni, Francesco and Wallace, Amanda (2022) Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement. PLoS ONE, 17 (12). ISSN 1932-6203

[img]
Preview
Text
Revised Hammersmith Scale for spinal muscular atrophy---.pdf - Published Version
Available under License Creative Commons Attribution.

Download (829kB) | Preview

Abstract

The Revised Hammersmith Scale (RHS) for Spinal Muscular Atrophy (SMA) was designed as a psychometrically robust clinical outcome assessment to assess physical abilities of patients with type 2 and 3 SMA. The reliability properties of the RHS have not yet been reported. A prospective RHS reliability study was undertaken in a UK cohort of experienced neuromuscular paediatric Physiotherapists. Reliability testing was conducted via a virtual survey platform two weeks apart. Through the virtual platform participants scored videos of two RHS assessments, one of a child with SMA 2 and one of a child with SMA 3. Inter and intra-rater reliability was analysed using a type 3 Intraclass Correlation Coefficient (ICC). Intra-rater agreement was further analysed using Bland Altman (BA) Limits of Agreement (LOA) and plots. The acceptable inter and intra-rater variability was set as a change of ± 2 by the international team of expert physiotherapists who developed the RHS. Inter-rater agreement, n = 22 raters, type 3 ICC was 0.989 (95% CI 0.944 to 1.00), 97.7% of scores were within the acceptable limits of ± 2 points. Intra-rater agreement, n = 21 raters, type 3 ICC ranged from 0.922 to 1.0, with 97.6% of scores within the acceptable limits of ± 2 points. The mean SMA 2 intra-rater difference was -0.10 (-0.6 to 0.4), with lower LOA -2.24 and upper LOA +2.04. Intra-rater difference between tests for SMA 3 intra-rater difference was -0.05 (-0.6 to 0.5), with lower LOA -2.48 and upper LOA +2.38. Intra-rater scoring precision fell within BA agreement limits of ±2 points. The results demonstrate that the RHS is highly reliable when used by experienced UK physiotherapists, and variability of test scores regarding inter and intra-rater reliability was confirmed to lie within ±2 points.

Item Type: Article
Uncontrolled Keywords: The Revised Hammersmith Scale, RHS, Spinal Muscular Atrophy, SMA
Subjects: R Medicine > R Medicine (General)
Divisions: Faculty of Health & Science > Department of Health Studies
Depositing User: David Upson-Dale
Date Deposited: 23 Mar 2023 08:43
Last Modified: 23 Mar 2023 08:43
URI: https://oars.uos.ac.uk/id/eprint/3046

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year